COMPLIANCE GUIDE

AS/NZS 3012 Explained

Working on a construction or demolition site? AS/NZS 3012 is the electrical safety standard that applies. Here's what it means for your tools and leads.

What AS/NZS 3012 covers

AS/NZS 3012 is the standard for electrical installations on construction and demolition sites. Construction sites are temporary, constantly changing and tough on equipment, so they get their own standard. It covers two main areas:

  • The site's electrical installation: how temporary power is supplied, distributed and protected, including switchboards and outlets.
  • Equipment used on site: how tools, leads, RCDs and other portable equipment are inspected, tested and tagged.

How it relates to AS/NZS 3760

AS/NZS 3760 is the general standard for inspecting and testing electrical equipment in workplaces. AS/NZS 3012 builds on it for construction sites, with requirements that reflect the higher risk. If you're working on a construction site, both are relevant. Read more about AS/NZS 3760 in our compliance guide.

Key requirements for tools and equipment

3-monthly testing

Portable equipment, leads and RCDs on construction sites are tested and tagged every 3 months, much more often than in most workplaces.

RCD protection

Portable equipment on site should be protected by an RCD (safety switch), either at the switchboard or with a portable RCD. RCDs are regularly checked with their test button and trip-time tested. See RCD testing.

Colour-coded tags

Many sites use a different tag colour each quarter, so it's easy to spot out-of-date equipment at a glance. See the current colour on our test and tag colours page.

Leads and cable management

Leads need to be suitable for site conditions and protected from damage, for example by keeping them off the ground on lead stands and away from water and vehicle routes.

What this means for subcontractors

  • Most head contractors won't let untagged or out-of-date equipment on site.
  • Your own tools and leads are your responsibility, so keep track of when they're next due.
  • Do a quick visual check before every use, and take anything damaged out of service.
  • Keep your test records handy in case the site asks for them.

This guide is a plain-English summary and not a substitute for the standard itself. Check the current edition of AS/NZS 3012 and your site's requirements for full details.

COMMON QUESTIONS

What is AS/NZS 3012?

AS/NZS 3012 is the joint Australian and New Zealand standard for electrical installations on construction and demolition sites. It covers how power is supplied and protected on site, and how equipment used on site is inspected and tested.

What is the difference between AS/NZS 3012 and AS/NZS 3760?

AS/NZS 3760 covers in-service safety inspection and testing of electrical equipment in all kinds of workplaces. AS/NZS 3012 is specific to construction and demolition sites, and covers both the site's electrical installation and the equipment used there.

How often does equipment need testing under AS/NZS 3012?

Equipment used on construction and demolition sites is generally inspected and tested every 3 months, and many sites use a colour-coded tag for each quarter.